L-Cor 8300 | |
---|---|
Flowrate | 24 kg/h to 2,550 kg/h |
Flow accuracy liquid | ± 0.2% ± ZS |
Flow repeatability liquid | ± 0.1% ± ½ ZS |
Flow accuracy gas | ± 0.5% ± ZS |
Flow repeatability gas | ± 0.25% ± ½ ZS |
Density range | 300 kg/m³ to 2,000 kg/m³ |
Density accuracy | ± 4 kg/m³ |
Nominal diameter | 1/2″ |
Ambient temperature | -40 °C to +55 °C |
Process temperature | -200 °C to +200 °C |
Process pressure (absolute) | Max. 430 bar (at 20°C) |
Process connection | Rc 3/8 Rc 3/4 |
Wetted parts | 1.4404 (316L) |
Approvals | ATEX, IECEx, CSA (C-US), NEPSI (CCC) |
Outputs | 2x analog, 2x pulse (frequency), 1x status output |
Inputs | 1x status input |
Digital communication | Bell 202, Modbus RTU (RS-485), Profibus PA, Fieldbus |
Transmitter version | Integrated, separately mounted, mounted in control cabinet |
Certifications | OIML R117-1:2019 (according to WELMEC 8.8 & 7.2) |
* ± ZS applies for flow rates below 5% of the maximum range. Accuracy valid at reference conditions. ZS = (Zero stability)/(Current flowrate) × 100%