Standard test methods | ASTM D86 (Group 0, 1, 2, 3, 4), ASTM D850, ASTM D1078, EN ISO 3405 (Group 0, 1, 2, 3, 4), IP 123, IP 195, JIS K 2254, GOST 2177, ASTM D524, ASTM D4530 |
User interface | 10″ TFT color touchscreen, solvent-proof |
Heating system | Low mass/low voltage heating system with automatic positioning of heater and safety shield Automatic initial heater settings and heater regulation Cooling fan to quickly reach safe handling temperature after test |
Condenser system | Liquid-free cooling with Peltier technology Temperature range: 0 °C to 80 °C, resolution: 0.1 °C |
Receiving chamber | Liquid-free cooling with Peltier technology Temperature range: 0 °C to 80 °C, resolution: 0.1 °C Corrosion-proof Automated reduced VOC emission |
Vapor temperature | Pt100, class A (metal or glass) Temperature range: 0 °C to 450 °C, resolution: 0.1 °C Integrated calibration memory with 20 calibration points and automatic read-out (ID detection) Automatic correction by barometric pressure |
Sample volume | Optical static detection system with contact image sensor (CIS) technology Sample volume scan before test start to measure initial volume (converted to 100 %, if necessary) Residue scan in receiving chamber with automatic calculation of loss Volume range: 0 mL to 103.5 mL, resolution: 0.01 mL Accuracy: ±0.1 mL |
Ambient pressure | Built-in pressure sensor, range: 30 kPa to 110 kPa, resolution: 0.1 kPa |
Ambient humidity | Built-in humidity sensor, range: 0 % to 95 % (rel. humidity) |
Ambient temperature | Built-in temperature sensor, temperature range: -20 °C to +80 °C, resolution: 0.1 °C |
Status light | Yes |
Test results | >4000 |
User defined test methods | >200 |
Fire extinguisher | Built-in fire extinguisher with IR sensor for fire detection Connection of 4 bar to 6 bar CO2 or N2 |
Condition monitoring system | Detection of flask size, flask support board, vapor temperature sensor, heater shield, heater lift, condenser cleaning, receiving chamber door, receiving cylinder, drip plate, detection if fire extinguishing gas is connected |
Operating temperature | 10 °C to 35 °C |
Relative humidity | 10 % to 80 % relative humidity at 35 °C |
Voltage | 100 V to 240 V, 50/60 Hz |
Total power | 900 W |
Altitude | 0 m to 5000 m |
Dimensions | approx. 406 mm × 525 mm × 645 mm (W × D × H) |
Weight | approx. 40 kg |
Connectivity | 1 × Ethernet, 4 × USB, Bluetooth, Wi-Fi, AP Connect, LIMS |
Automatic calculation | Cetane index, driveability index |
Accessories | Dry point sensor, 200 mL flask, bar code reader, printer, receipt printer, keyboard, various certified reference materials (CRM) |
دستگاه Diana 700
ویژگی های کلیدی دستگاه
- بر اساس استاندارد D86
- بالاترین سطح ایمنی
- دستگاه تمام اتوماتیک با دقت بسیار بالا
- دارای هیتر اتوماتیک
- قابلیت ذخیره 4000 نتیجه
توضیحات
نظرات (0)
نمره 0 از 5
0 نقد و بررسی
نمره 5 از 5
0
نمره 4 از 5
0
نمره 3 از 5
0
نمره 2 از 5
0
نمره 1 از 5
0
اولین نفری باشید که دیدگاهی را ارسال می کنید برای “دستگاه Diana 700” لغو پاسخ
حمل و نقل و آموزش رایگان
حمل و نقل تمامی تجهیزات آزمایشگاهی و ابزار دقیق ما رایگان است و تا درب آزمایشگاه و خط تولید انجام می شود.
همچنین برای تمامی محصولاتی که خریداری می کنید به طور رایگان آموزش کامل کاربری، نحوه کار دستگاه و دستورالعمل های کاربری آموزش داده می شوند تا در حین تجربه کاربری بهتر محصولات، طول عمر دستگاه ها افزایش پیدا کند.
شرایط گارانتی
تمامی دستگاههای آزمایشگاهی و ابزار دقیق شامل یک سال گارانتی و ده سال خدمات پس از فروش می باشد.
پشتیبانی و سرویس
طبق آموزش های کمپانی Anton Paar کارشناسان ما جهت سرویس، کالیبراسیون، تعمیرات و تعویض قطعات در کنار شما خواهند بود.